HCV-E-AX

Kolom oliepeilglazen

Omschrijving

1Main specifications

Material

Transparent polyamide based (PA-T) technopolymer. Highly resistant to shocks, solvents, oils with additives, aliphatic and aromatic hydrocarbons, petrol, naphtha, phosphoric esters.

Avoid contact with alcohol or detergents containing alcohol.

Screws, nuts and washers

Zinc-plated steel.

Packing rings

Step-shaped for the seal on the reservoir walls and NBR synthetic rubber O-ring screw underhead.

Suggested roughness of the packing ring application surface Ra = 3 µm.

Float

Glass-fibre reinforced polyamide based (PA) technopolymer, black colour, with a built-in magnetic element to activate the electric contact when the float reaches the contact threshold located at about 50 mm above the axis of the lower screw (data referred to mineral oil type CB68, according to ISO 3498, temperature 23°C).

Sensor bracket

Watertight in glass-fibre reinforced polyamide based (PA) technopolymer, black colour, with a built-in relay (reed) with two conductors (NO and NC versions) at the output or three connectors (SW version).

For a correct assembly see Warnings.

Swivelling connector

With built-in cable gland and contact holders. Front or side output (right or left) including protection against water sprays (protection class IP 65 according to EN 60529 table-).

Contrast screen

White lacquered aluminium. The housing, in the appropriate external rear slot, guarantees the best protection from direct contact with fluid.

It can be taken out from the inclined side, before assembly to allow the insertion of level lines or words.

Standard executions

  • HCV-E-AX-NO: with electric contact normally open (NO).
  • HCV-E-AX-NC: with electric contact normally closed (NC).
  • HCV-E-AX-SW: with change-over electrical contact (SW).

Maximum continuous working temperature

90°C (with oil).

2General information

Features and performances

The column level indicator HCV-E-AX, in addition to the visual control, generates an electric signal when the oil level drops to a minimum.

Ultrasound welding to guarantee a perfect seal.

Maximum fluid level visibility even from side positions.

Lens effect for a better visibility of the fluid level.

Technical data

In laboratory tests carried out with mineral oil type CB68 (according to ISO 3498) at 23°C for a limited period of time, the weld stood up to 18 bar.

For use with other fluids and under different pressure and temperature conditions, please contact ELESA Technical Department.

In any case we suggest to verify the suitability of the product under the actual working conditions.

3Electrical features

Functioning of the MIN level electrical sensor

  • HCV-E-AX-NO: the electrical contact closes on reaching the minimum level.
  • HCV-E-AX-NC: the electrical contact is opened when it reaches the minimum level.
  • HCV-E-AX-SW (change-over electrical contact): the electrical contact switches between the two terminals.
Electrical featuresMIN level sensor
Tension feedAC/DC
Electric contacts

NO normally open

NC normally closed

SW change-over contact

Maximum applicable voltage

NO: 140 Vac, 200 Vdc

NC: 140Vac, 150 Vdc

SW: 140Vac, 150 Vdc

Maximum switching current1 A
Maximum current

NO: 1.2A

NC: 2A

SW: 2A

Maximum commutable power

NO: 10 Va

NC: 20 Va

SW: 20 Va

Cable glandPg 7 (for cables in sheath with Ø 6 or 7 mm)
Conductors cross-sectionMax. 1.5 mm2
Do not mount this indicator in proximity to magnetic fields.
 
4Other executions

Special executions on request

  • Level indicators with stainless steel screws, nuts and washers.
  • Level indicators for use with fluids containing alcohol.
  • UV resistant transparent technopolymer level indicators.
5Instructions of use

Connector assembly instructions

  • Remove the connector from the indicator by unscrewing the set screw placed on the connector, take the contact holders out and loosen the cable gland.
  • Slip on the cable into the connector (standard connector) and connect the wires to the terminals 1 and 2 (NO and NC version) or 1,2 and 3 (SW version) of the contact holder.
  • Assemble by pressing the contact holder into the connector in the required position.
  • Screw the connectors to the indicator and then tighten the cable glands.
 

Scroll onderstaande tabel om meer te zien

Code

Product omschrijving

Aantal

Prijs

Bestel

CAD

L#

e

l1

d'-0.2

f

Gewicht (g)

d

a

l

f ±0.2

C

B

C#[Nm]

m

H

l2

Filter
470014368 HCV.127-E-AX-NC-M12
€ 104,21
201.5 97 30 12.5 127 223 M12 21.8 50 127 31 20 12 28 25.5 29
470014367 HCV.127-E-AX-NO-M12
€ 87,89
201.5 97 30 12.5 127 223 M12 21.8 50 127 31 20 12 28 25.5 29
470014369 HCV.127-E-AX-SW-M12
€ 100,45
201.5 97 30 12.5 127 223 M12 21.8 50 127 31 20 12 28 25.5 29